facebook-pixel-image
 
Τηλέφωνο Εξυπηρέτησης Πελατών: 211 10 16 622

Fluke 729 Automatic Pressure Calibrator

Κατασκευαστής: Εικόνα της FLUKE
Fluke 729 Automatic Pressure Calibrator
Διαθεσιμότητα: Παράδοση 4 έως 10 ημέρες info
Κωδικός προϊόντος(SKU): 0638-FLK-729-30G
Αριθμός κατασκευαστή προϊόντος: FLK-729-30G
15167,68 €
(εώς δόσεις)
decrease increase
Share
Fluke 729-30G 30 psi, 2 bar range, no wireless communication

The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pres­sure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.

The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment con­trol automatically stabilizes the pressure at the requested value.

The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.
Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values.

Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.
With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.

Key Features:

Automatic pressure generation and regulation to 300 psi
Easily document the process using onboard test templates
Automatic internal fine-pressure adjustment
Measure, source and simulate 4 to 20 mA signals
24V loop power for powering transmitters for tests
Bright dual/triple-channel color graphical display
HART communication for testing HART
Fluke 729-30G 30 psi, 2 bar range, no wireless communication

The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pres­sure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.

The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment con­trol automatically stabilizes the pressure at the requested value.

The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.
Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values.

Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.
With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.

Key Features:

Automatic pressure generation and regulation to 300 psi
Easily document the process using onboard test templates
Automatic internal fine-pressure adjustment
Measure, source and simulate 4 to 20 mA signals
24V loop power for powering transmitters for tests
Bright dual/triple-channel color graphical display
HART communication for testing HART
Προδιαγραφές προϊόντων
Τύπος Οργάνου Βαθμονομητής
Προδιαγραφές προϊόντων
Τύπος Οργάνου Βαθμονομητής